Water quality monitoring covers a wide set of parameters depending on the water body: fish ponds and aquaculture focus on dissolved oxygen, pH, and temperature; wastewater treatment tracks DO, ammonia nitrogen, COD, and suspended solids; surface water and reservoirs watch turbidity, chlorophyll, and ions; industrial process water uses conductivity and ORP. Selecting the right sensor means first deciding which parameters you need, then choosing single probes or a multi-parameter unit, and finally matching wired RS485 or wireless LoRaWAN to your site.

Single LoRaWAN probes suit dispersed or off-grid sites where one or two parameters are enough; the probe and collector connect locally and report over LoRaWAN.
Multi-parameter units combine several probes on one collector and often include automatic cleaning and temperature compensation, which lowers maintenance in long-term immersion sites.
Wired RS485 transmitters integrate directly into PLC, DCS, or monitoring software using Modbus RTU or analog signals, where a wired control network already exists.
| Model | Type / link | Key measured parameters and range | Supply / physical |
|---|---|---|---|
| ZW-MPS Online Multi-Parameter Self-Cleaning Sensor (185) | RS-485, Modbus/RTU; digital, up to 8 parameters incl. temperature; automatic cleaning | DO 0–20 mg/L ±2%; Turbidity 0–200/1000 NTU; EC/salinity 0–5000 μS/cm, 0–200 mS/cm, 0–70 PSU ±1.5%; COD 0–200/500 mg/L ±5%; pH 0–14 ±0.1; ORP -1500~+1500 mV ±6mV; Ammonia nitrogen 0–100/1000 mg/L | See product page |
| LoRaWAN Solar Multi-Parameter Water Quality Sensor (206) | LoRaWAN; solar powered; up to 6 probes, 8 parameters; automatic cleaning; temperature compensation; aviation connector | Probe-specific ranges listed on the product page | Solar powered; see product page |
| Industrial DO Transmitter (106) | RS485; fluorescent DO | DO 0–20 mg/L, ±3%FS | 10–30 V; POM + stainless steel |
| LoRa Water Quality EC Sensor (118) | LoRaWAN, LoRa TDMA; OTAA/ABP Class A | EC 1–2000 μS/cm; resolution 0.1 μS/cm; ±1%FS | 12/24 VDC; -30~70 °C; 90×85×40 mm; wall mount |
| LoRa Water Quality pH Sensor (120) | LoRaWAN, LoRa TDMA; OTAA/ABP Class A | pH 0–14.00; error ±0.15 pH; repeatability ±0.02 pH | 12/24 VDC; -30~70 °C; 90×85×40 mm; wall mount |
| Ammonia Nitrogen Transmitter (108) | RS485; anti-corrosion plastic | NH3/NH4+ 0–10 / 100 / 1000 mg/L, ±3%FS | See product page |
Other probe families (parameter ranges listed on each product page): ORP, chlorophyll, residual chlorine, LoRa ammonia nitrogen, COD, ion, and LoRa dissolved oxygen probes cover additional water quality parameters.

LoRaWAN probes and multi-parameter nodes uplink through an IoT Gateway to the cloud for remote viewing and alarms. Wired RS485 transmitters connect to local control systems; a serial DTU can forward RS485 or serial data to the network where a remote station must reach the network.
Single probes or a multi-parameter unit? Use single probes when you only need one or two parameters and sites are dispersed; choose a multi-parameter unit for several parameters on one collector, especially with self-cleaning.
LoRaWAN or RS485? Use LoRaWAN for remote, off-grid, or widely dispersed monitoring; use RS485 when integrating into an existing PLC/DCS or wired control network.
Which parameters for aquaculture? Start with DO, pH, and temperature, then add chlorophyll or turbidity depending on pond and species requirements.
How often should water probes be cleaned? Frequency depends on biofouling and water clarity; inspect regularly and rely on the self-cleaning interval on self-cleaning models.
Define the parameters your water body requires first, then select single LoRaWAN probes, a solar multi-parameter node, or an RS485 transmitter that fits the existing control system. Review the ZONEWU multi-parameter self-cleaning sensor, solar multi-parameter sensor, DO transmitter, EC sensor, and pH sensor, or connect through the IoT Gateway for remote water quality monitoring.
Contact: Qui
Phone: 18146178586
Tel: 18146178586
Email: qui@zonewu.com
Add: 1501-3, Building F03, Phase III, Software Park, Jimei District, Xiamen City, Fujian Province, China